Which module will be used for Base expansion?
2014.07.28

 

u   Which module will be used for Base expansion? 

CM1-EP01A, CM1-EP02A and CM1-EP03A are used for Base expansion. 

Maximum 16 Base expansion is available.  

Distance between each Base is recommended less than 100m.  

 

CM1-EP3A is used for Power Redundancy. 

 

n    Base Expansion Setting 

Select the number of Base through Rotary Switch. 

Base No. 

Rotary Switch 

Base No. 

Rotary Switch 

#1 

#9 

#2 

#10 

#3 

#11 

#4 

#12 

#5 

#13 

#6 

#14 

#7 

#15 

#8 

#16 

  

n    Format of Expansion Base number in CICON 

Format: H+[Base number]+[Slot number] 

  

[Example] 

  

Base No. 

Slot No. 

Format 

Local Base 

No.5 Slot 

H0005 

No.9 Base 

No.8 Slot 

H0908 

No.10 Base 

No.9 Slot 

H0A09 

No.16 Base 

No.11 Slot 

H100B 

  

Download manual