Downloads

Introducing CIMON UltimateAccess Web, a powerful SCADA software platform enabling seamless monitoring, control, and data visualization through any HTML5-based web browser.

Demo Projects

Alarm

08-21-2025

.zip

Changelog

Version 1.1.6

New Feature

  • Web Server
    • Added a feature to check the UA Web version information in the web viewer or browser.
    • After clicking the utility button, open the System Log or Audit Trail page, and click the [Information] button in the lower right corner to check the version info.
  • Utility
    • Added an option to prevent xlog from remaining on the local PC when CimonX is executed.
    • This option can be enabled or disabled in the Runtime environment settings.
  • Command Expressions
    • Added commands to control alarm summary object
      • Usage: AlarmCommand(“Alarm Summary Object Name”, Command )
      • Command : 0
    • Displays the current alarm.
      • Command : 1
    • Displays the historical alarm.
      • Command : 2
    • Acknowledges the alarm you specified in the alarm tag. The command is applied only to the current alarm object.
      • Command : 6
    • Acknowledges all alarms displayed in the alarm summary window. The command is executed only in current alarm. If the same alarm is displayed on the other object, alarm acknowledge is applied simultaneously.
      • Command : 7
    • Clear the alarm summary object.
    • Added commands to export alarms and user data tables.
      • Usage: ExportUserDataTable("Table Name", "Start Time", "End Time", "Save Path")
      • Usage: ExportAlarmData("Start Time", "End Time", "Save Path")
  • Alarm Summary Object
    • Added an option to show or hide the alarm acknowledgment button when configuring the Alarm Summary object.
      • Users can select whether to display the alarm acknowledgment button in the Alarm Summary object on the web page.
    • Added an option to start in historical mode.
      • Users can select whether the Alarm Summary object initially displays in real-time or historical mode within the web page.

Changes

  • Trend / Chart
    • Improved the loading speed of collected data accumulated over a long period.
  • Tag Database
    • Modified to allow the use of foreign languages other than the alphabet in tag names.
  • Command Expressions
    • Modified the system so that the AlarmSound() command is not executed on pop-up pages.
    • Fixed an issue where only one sound was output when the PlaySound() command was executed multiple times.
    • Fixed an issue where using PlaySoundEX("SoundFileName", 0) only operated once.

Bug Fixes

  • Command Expression
    • Fixed a bug where the AlarmAck("Tag Name") setting did not work in the alarm clear action.
  • Recipe
    • Fixed a bug where the screen was displayed abnormally when multiple production histories were shown on the web page for viewing recipe production history.
  • IEC61850 Communication Driver
    • Fixed an issue where communication failed when attempting to communicate with an actual relay after successfully creating tags by selecting "Load cid" and choosing objects to communicate with.
    • Fixed an issue causing an abnormal termination (crash) when clicking "Edit" in a communication driver configured with cid and selecting "Relay Connection".
  • Tag database
    • Fixed a bug regarding the saving of the final status of tags.
  • Script
    • Fixed a compile error that occurred when tabs and space characters were mixed in Python scripts.
  • Web Client
    • Fixed a bug where alarms were randomly displayed in chronological (oldest first) order when opening a page containing an alarm summary object.
  • Switch/Lamp
    • Fixed a bug where only one command was executed when multiple commands were configured in a switch/lamp object.
  • Mobile
    • Fixed a bug where alarm Push notifications were sent to mobile devices even when there was no mobile key lock.
  • FEP
    • Fixed a bug where the program terminated during FEP communication with previous UltimateAccess software.
  • Others
    • Fixed a bug where two or more spaces entered in a string object were incorrectly recognized as a single space.

Version 1.1.5

Changes

  • Command Expressions
    • ReopenPage Command Added: A new command has been added to close a page that is already open as a pop-up and reopen it in pop-up format.
    • Usage: ReopenPage("PageName").
  • Part 11 – Windows Account Integration
    • Active Directory Integration: Improved the integration functionality for accounts created within Active Directory settings in a Windows Server OS environment.
    • Web Viewer Auto-Login: Users logged into a Windows Server OS are now automatically logged into the Web Viewer without requiring a separate web server login process.
    • Auto-Logout: Clients will now automatically log out when the Windows Lock command (Windows Key + L) is executed.
  • Part 11 – New Group Permission Settings
    • System Hotkey Option: Added a new option: "Use Web Viewer System Hotkeys".
    • Restricted Access: Users belonging to a group where this option is disabled will be unable to use the following system hotkeys:
      • Alt + Tab
      • Alt + F4
      • Alt + Esc
      • Ctrl + Esc
      • L Window (Left Windows Key)
      • R Window (Right Windows Key)

Version 1.1.4

Changes

  • Commands
    • Changed the maximum number of tags for the OpenPageEx command to 300.
    • Added commands to print the screen displayed on CimonViewer.
      • Hardcopy: Prints the entire screen currently being viewed.
      • HardCopyEx(X, Y, Width, Height): Prints a specified location of the screen to the printer.
  • Others
    • Changed settings to allow the Administrator account to change its own password.

Bug Fixes

  • Redundancy
    • Fixed a bug where the Standby PC would unexpectedly shut down if the Primary PC was forcibly shut down.
  • Others
    • Fixed a bug where abnormal values occurred when using UINT16 data scaling, real data functions, or the Scale function.
    • Fixed a bug where EX Page Tags were not applied to buttons for 'Write Tag Value', 'Write Digital Value', and 'Write Momentary Value'.
    • Fixed a bug where comment changes were not applied when saving the entire page.
    • Fixed a bug where the screen became dark when touching the screen while running Web Viewer on CIMON Touch products.
    • Fixed a bug where the screen zoomed in when using OpenPageEx or ClosePage in Web Viewer.
    • Fixed a bug where line breaks could not be used in comment tables.
    • Fixed a bug where annotations disappeared when changing Trend Tag values.
    • Fixed a bug where the UP action of a popup page command was propagated to the Web Viewer.
    • Fixed a bug where the Modbus TCP Client communication driver communicated directly with IO devices while in Standby mode.
    • Fixed an issue where respective alarm sounds played simultaneously when two alarm tags were triggered.

Version 1.1.3

Bug Fixes

  • IEC 61850
    • Modified to leave a log when connection fails while attempting to connect to an external relay device.
  • OPCUA Client
    • Fixed a bug that prevented Discover URL information from being received when connecting to some OPCUA servers.
  • Object
    • Fixed a bug where rotation settings were not applied to library objects in the designer.

Version 1.1.2

Changes

  • Object
    • Additional properties that allow you to rotate tag values are specified.
    • Additional properties that allow you to rotate GIF Image are specified.
  • Web server
    • Modified to allow the public certificate password set in the public certificate to be entered when setting up HTTPS.

Bug Fixes

  • ETC
    • Fixed a bug where the width/height values would change by 1 when ungrouping multiple objects.
    • Fixed a bug where data types could not be used in the tag database editor.
    • Fixed a bug where the alignment status in the web server tag input window changed to left alignment.
    • Fixed a bug that caused the GetUserName function to display as ???? after switching pages.
    • Fixed a bug where alert settings set in tag values were reset when converting past projects.
    • Fixed a bug where when a number greater than 1,000,000 (one million) was entered into the input/output table object, the value was forcibly converted to exponential notation and saved during server processing.

Version 1.1.1

Changes

  • WatchM
    • Modified the function to terminate all remaining web server and script engine processes when WatchM is re-executed.

Bug Fixes

  • Communication Driver
    • Fixed a bug that caused the status to be displayed incorrectly when communication failed in the Modbus TCP Client driver using block communication.
    • Fixed a bug that caused the write speed to slow down when multiple tag write operations occurred in the Modbus RTU Master driver.
    • Fixed a bug that prevented connection to the target Server/Client during runtime execution after setting up communication with the OPC DA Server/Client driver.
  • ETC
    • Fixed a bug that caused data errors when pasting group tags from Excel into the tag database.
    • Fixed a bug where rotation would not be applied when closing and reopening the page after adding a library object to the page in CimonD.
    • Fixed a bug where the OpenPageEx command would not execute even if set to an alert action.
    • Fixed a bug that prevented negative numbers from being entered on the web when entering a negative number in the minimum data input value.

We use essential cookies to ensure proper site function. You may choose to allow all cookies for an optimized experience.