Downloads

Introducing CIMON Canvas, a revolutionary HMI programming software designed for our new eXT, nXT, and eXT2 series of Xpanel HMI displays.

Installer

Demo Projects

Default HMI Project

11-05-2025

.cnvs

Chess

08-21-2025

.cnvs

Changelog

Overview

Fixed

  • Fixed an issue where SMTP emails failed to send when addressed to users or groups instead of direct email addresses.
  • Fixed issue where certain bindings and expressions were lost when copying and pasting to another project.
  • Improved page loading speed.
  • Improved page transition speed.
  • Fixed the issue where the app intermittently crashes when running "openConfig" scripts.
  • Fixed an issue where the script did not execute properly when the "closePage" and "openPage" functions were executed consecutively.
  • Fixed an issue where remote tag values ​​registered to Waveform objects were not updating.
  • Fixed slow project loading speed.
  • Fixed incorrect menu name from 'Tag Editor' to 'Tag List' in the View menu.  
  • Fixed a runtime crash that occurred when the table column width in the alarm object reached a specific value.
  • Fixed an issue causing infinite page switching loops during remote page control.
  • Fixed an issue with full permission vulnerability in getUserRightsMask in OPC UA server.
  • Fixed a vulnerability to make password timing attacks impossible in OPC UA server.
  • Fixed an internal session timing race condition issue in OPC UA server.
  • Changed the wording of warning messages for Runtime upgrades and disabled project transfers.
  • Updated the copyright.

Designer

Added

  • Added support for the Yaskawa Ethernet driver.
  • Added support for the Siemens PPI Direct Serial driver.

Changed

  • Changed OPC UA Server settings to always be serialized to prevent misinterpretation by the gateway.

Fixed

  • Fixed an issue where icons were not updating in certain UIs when changing tag device properties.
  • Fix immediate simulator startup failure caused by an occupied Mosquitto broker port from a previous incomplete termination.

Runtime

Fixed

  • Fixed the config dialog being cut off in ext04
  • Fixed some system log messages not being translated
  • Fixed misaligned vertical grid lines in the alarm summary object
  • Fixed configured coordinates being ignored when opening popup pages
  • Fixed dynamic color settings not working for SVG images

Gateway

Added

  • Added the Yaskawa Ethernet driver
  • Added the Siemens PPI Serial driver

Fixed

  • Fixed an issue with intermittent recipe data loss in Omron PLCs
  • Fixed bug in the OPC UA Trust store and anonymous login failures

Platform

Fixed

  • Fixed CANVAS project export to USB failure randomly